Sears is proud to be the dependable name in Reynoldsburg, OH for everything heating and cooling related. Our highly-skilled professionals have what they need to tackle any job, diagnose any problem and complete any repair. Your comfort is our number one priority.
Find out why we’ve been held in such high esteem since we were founded in 1950. Read reviews from the good folks of Reynoldsburg, OH below.
Recent Jobs and Reviews in Reynoldsburg, OH
Our Local Reviews by City
- Blacklick, OH (2)
- Columbus, OH (171)
- Delaware, OH (2)
- Dublin, OH (16)
- Gahanna, OH (2)
- Galena, OH (8)
- Galloway, OH (3)
- Grove City, OH (5)
- Groveport, OH (1)
- Hilliard, OH (5)
- Johnstown, OH (1)
- Lewis Center, OH (3)
- Marble Cliff, OH (2)
- New Albany, OH (10)
- Plain City, OH (2)
- Powell, OH (7)
- Reynoldsburg, OH (1)
- Upper Arlington, OH (2)
- West Jefferson, OH (1)
- Westerville, OH (45)
- Worthington, OH (7)
Job Locations and Reviews
Performed yearly maintenance and safety checks on 21 braynt furnace. Cleaned flame sensor and flu trap. 10.2%o2 46 ppm co in flu 52 degree deltat. Furnace cycled into second stage properly. Running with 55 degree deltat. 7.05%o2. 71 ppm co in flu. No issues found at this time.
Performed yearly maintenance and safety checks on 06 Goodman furnace. Cleaned flame sensor. 8.62%o2. 15 ppm co in flu. 0 ppm co in supply. Replaced 12241 filter. No issues at this time.
Yes Installed new 50 gallon water heater. Replaced ball valve shut off for water. Replaced tank. Flu is Properly drafting no leaks at water connections. No gas leaks at this time.
Customer had roto rooter outstated water coming from ac. Found pump full. Hard wired into board. Ground came loose. Sh3a to Resecured ground wire and test pump. Customer accepted. Pump cleared water. Found water dripping into floor from behind wall. Advised customer pump is working properly without issues. Additional issues behind wall. Pump drains into plumbing outside of wall. No water from pump/vinyl. Advised issues seem to be coming from inside wall/ behind sink.
Found blower seized up not operational. Motor is obsolete. Cannot find specs will need to remove blower and take in to compare for Universal motor.. advised no warranty comes with universal motors. Repair options would be HC12. cust9mer would rather put money into replacement. If filling out financing now. Left quote for 80%45k furnaces
Performed yearly maintenance and safety checks all 2023 AC no concerns at this time
May call for cooling upon arrival found outdoor unit cycled on compressor did not cycle, found voltage absorption system drained not providing assistance needed quoted HN13 customer chose option b to replace part with oem part and basic cleaning of condenser. Performed repair cycled system. 20 degree deltat upon departure.
HN13a
Cost to install air conditioning. Existing air conditioning is icing up that is due to low refrigerant. Cost to replace air condition.
Performed yearly maintenance and safety checks on 2021 Bryant AC system. Found 40/5 voltage absorption system reading 38.9/4.9. 72 in rush amps. Customer asked about humidifier water panel replacement, customer will replace humidifier panel themselves, has it been done since install advised to do it as soon as possible.
Made call for cooling compressor making horrible grinding type noise for roughly 1 second and then shutting off. Found 35/5 voltage absorption system within manufacture specifications. Proper voltage to unit. Found wire on bottom of contactor typically found on top. Switched wire. Compressor sounded slightly better ran for roughly 2-3 seconds before shutting down. Advised compressor damage has occurred. Will call tomorrow for quote on repair. Left new quote for 2.5 ton unit replacement customer will compare and contrast after quote.
Scac
Performed yearly maintenance and safety checks on 23 Bryant. 40/5 voltage absorption system reading 40/5. 51 inrush amps. Left new 16251 filter.
Responded to no cool situation. Resupply power to unit customer stated breaker would trip immediately found breaker would trip immediately for 4 attempts. Breaker stayed on for 5th attempt. Found short at disconnect box high voltage rubbed through to metal. Older unit owner believes it’s original to home roughly 2009. No data plate legible. Hb5a-e. Due to age and cannot order parts cust9mer chose option a. Retrieved parts and performed repair. 20 degree deltat. 68/48. No issues at this time
Due to tornado watch in area advised customer we would reach out to schedule tomorrow. She will be home at 415 Upon arrival customer stated furnace was not operating at all found 120 V coming to board but no LED or low-voltage found bad transformer presented options HD3 a through E customer chose option C performed repair of transformer voltage absorption system flame sensing system and surge protection. Found voltage being stolen as well as an extra short trace back to voltage distribution system of AC system. Presented options HD2 a through E customer chose option C performed voltage distribution system repair as well as cleaned condenser coil and replaced voltage absorption system. Cycled system system currently running with 21° delta T. No further issues at this time
Performed yearly maintenance and safety checks on 2019 Bryant AC system found 45/5 voltage absorption system reading 43.7/5. 70.2 in Rush amps 88–108 hard start reading 105. Replaced customer supplied 213 filter. 70 RA 49 SA 21 degree deltat. No issues found at this time.
Performed yearly maintenance and safety checks on 2022 Bryan AC system. Found 45/5 voltage absorption system reading 43.7/4.8. 113 inrush amps. 65/44 21 degree deltat. No issues at this time. Customer will talk with husband about adding surge protection.
Performed yearly maintenance and safety checks on 2012 Bryant AC system found45/5 voltage absorption system reading 45/5. 189-227 hardstart reading 199. 79 inrush amps nno issues found at this time.
Performed yearly maintenance and safety checks on 2012 Bryant ac system. 45/5 Voltage resorption system reading 44.3/5-84 inrush amps. Left new 16251. Added tabs to drain
Performed yearly maintenance and safety checks on 2018 comfort maker AC system. Found 35/5 voltage absorption system reading 34.5/4.8. 81 inrush amps. Cleaned condenser replaced 16251 filter no issues found at this time.
Left quote for new 114/126 3ton system. Customer on schedule for next Friday 8am. Customer to go with 126 paying in cash
Responded to no heat. Gas company stated pressure loss past shut off. Checked for leaks via electronic gas leak detector. Found no sign of leak. Double checked for leaks with big blu micro leak micro bubble soap solution. Found no sign of leak around all joints and fittings. Customer was present to find no bubbles as well. Customer stated gas tech said it may be in gas control. Advised typical process is to shut off all gas shut offs and test to shut offs then once passing test use electronic leak detector on equipment side of line. Advised if he allowed any psi to gas valve gas valve would not be able to hold pressure back. Cannot confirm or deny. No obvious sign of gas leak at gas valve. Offered to replaced gas valve Customer is not interested at this time. Advised customer of service club as well as furnace age. 02 furnace. Started furnace up. Found 0 ppm co in flu. Furnace operating properly at this time. No gas leak found near shut off via bubbles or electronic detector. Colle