Completed annual maintenance on a 2010 Bryant furnace. During testing of the unit the technician found dirt beginning to form on air circulation system, and rust on burner cells although no cracks were present at this time. This is something to monitor moving forward. Customer maintains their humidification system. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2015 Bryant furnace. During testing of the unit, the technician found no electrical protection device, as well as dirt beginning to form on air circulation system. Technician presented options hb7a-e. Customer will think about options and call back if she decides to move forward with install. Customer wanted quote for air conditioner replacement. Jamie out later today per office. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2015 Bryant furnace. During testing of the unit, the technician found no electrical protection device, as well as dirt beginning to form on air circulation system. Technician presented options hb7a-e. Customer will think about options and call back if she decides to move forward with install. Customer wanted quote for air conditioner replacement. Jamie out later today per office. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2014 Bryant furnace. During testing of the unit the technician found no electrical protection device, the air filter replaced to date back to over a year, and air beginning to build on air circulation system. Technician presented options hb7a-e. Customer will call back at a later time for installation. Customer renewed service plan for two years today. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2004 Bryant furnace. All electrical, mechanical and safety components of the system check out at this time. Technician replaced 16254 air filter covered under contract. Technician observed air circulation system beginning to accumulate dirt/dust, this is something to monitor moving forward. Flue pipe also beginning to show signs of breakdown, but is still sell them at this point. No issues at time of departure.

Joel T.
Furnace safety inspection all systems operating at this time.
Austin L.
Complete Daniel maintenance on a 2013 Bryant furnace. During testing of the unit the technician found no electrical protection device, the air filter dating back to last years visit, and dirt beginning to build within the air circulation system. Technician presented options hb7a-e. Customer chose option a. Technician cycled unit successfully after repair was complete. Customer reminded customer one inch filters are changed monthly. Customer stated he can’t change them due to being disabled and will ask family/friends to help. Technician collected service club renewal today. No issues at time of departure.

Wally T.
Annual maintenance check on a Trane furnace

Joel T.
Replaced warranty condenser fan motor on rheem ac
Robby D.
Completion Notes: Edit Completion Notes Made call for cooling customer had disconnect pulled. Looks like custoemr had voltage distribution system replaced. Technician bypassed fan control board. Advised blower motor has taken damage as well as compressor. Left options for replacement furnace and ac. Customer will review options and call back if finalized estimate is needed

Joel T.
Replaced failed blower motor and returned unit to service.
Austin L.
Completed annual maintenance on a 2022 Bryant heat pump. During testing of the unit technician found no electrical protection device. Technician presented options hb7a-e. Customer will think about repair and will contact office if she wants to move forward. Technician reminded customer one inch filters are changed monthly, filter size 16x3/8x21.5. No issues at time of departure.
Austin L.
Technician back to complete repairs. Technician installed outdoor fan motor, electrical distribution system, and performance kit. Technician cycled unit successfully after repairs were complete. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2010 Bryant air conditioner. During testing of the unit the technician found the performance kit previously installed to be just within manufactures specifications, the voltage distribution system to show signs of age/pitting, and oil leaking from outdoor fan motor. Technician presented options Hc7 a-e. Customer will call back after vacation to have repairs complete. Option C will cover motor, performance kit, and electrical distribution system. No issues at time of departure.
Austin L.
No cool on the 2022 Bryant air conditioner. Upon arrival technician found no low voltage leading to outdoor unit. Technician found water device tripped. Technician verified no leak present. Technician reset device and cycled unit successfully. No issues at time of departure.
Robby D.
Completion Notes: Edit Completion Notes Performed yearly maintenance and safety checks on 2022 Bryant air conditioning system. Found 35/5 old is absorption system reading 34.6/4.9. Found no sign of overheating or pitting on voltage distribution system or disconnect. Found 73 inrush amps. Informed customer of air purification and surge protection accessories. Customer is not interested at this point. No concerns at this time
Robby D.
Performed yearly maintenance and safety checks on 2012 Bryant ac system. Found 40/5 voltage absorption system reading 40/5. Found no sign of pitting or overheating inside disconnect or voltage distribution system. 71RA 51SA. No concerns found at this time.
Robby D.
Upon arrival made call for cooling. Found indoor unit cycled on properly. Heat pump outdoors. Found disconnect laying on ground. Put disconnect back in. Unit cycled on in heat. Found multiple concerns with equipment. 2-3 inch gap on underside of filter rack. No filter in rack. Dirty blower motor wheel. Broken condensation drain. Customer only wants cooling to system. Moved o wire to y terminal to get cooling when calling. Sh3a. Found 74 RA 56 SA. Customer is aware he will loose operation of heat function of heat pump., still has furnace heat for house. customer will correct drain and put new filter in.
Robby D.
Made call for cooling upon arrival. Found indoor system cycled on properly outdoor system fan was running compressor failed to start. 45/5 voltage absorption system reading 26nf/4.7 not allowing compressor to cycled. Informed customer of findings quoted hn13 a-e. Customer has $65 limited manufacture warranty credit towards any repair. Customer chose option E also informed customer of annual maintenance and safety checks. Customer chose to sign up today. Performed Repair and SCAC Today. Found system running with 74 RA 54 SA. No further concerns at this point in time.
Robby D.
Upon arrival thermostat set to off. Made call for cooling. Found indoor system cycled on properly. Found outdoor system failed to cycle. Found board throwing code for faulty coil and ambient sensors. HE7 a-e. Customer chose option C. $65 limited manufacture warranty credit. Retrieved parts and performed repair. Cycled heat pump to ensure operation. Also added surge protection and replaced voltage distribution system under repair.
Robby D.
Performed yearly maintenance and safety checks on 2018 American Standard air-conditioning system. Found 40/5 voltage absorption system reading 39.8/5. No sign of overheating or pitting in disconnect or on voltage distribution system. No concerns at this point in time.
Austin L.
Completed annual maintenance on a 2018 comfortmaker air conditioner. During testing of the unit the technician found no electrical protection device. Technician presented options hb7a-e. Customer chose option a. Technician completed install and cycled unit successfully. Technician presented fresh air corporation information for duct cleaning. Customer will contact office to have technician come out and replace air filter after Fresh Air completes their work. No issues at time of departure.
Robby D.
Made call for cooling upon arrival. Found furnace cycled on ac unit failed to cycle through diagnostic steps found unit shut off due to low pressure. Found no sign of leaks inside. Found multiple hits around service valves. Tightened schrader valve 1-1/4 turn charged system to 10 degree Subcooling 14 degree superheat. 72 RA 52 SA 20 degree delta t upon departure. No further concerns covered under warranty no charge per office.