No cool on an unknown year, make and model air conditioner. Initial inspection of the outdoor unit technician found multiple plants and thick limbs growing into and through the unit. Technician tried to cycle unit but was unsuccessful. Technician verified incoming voltage, and found compressor to have failed. Technician also found voltage distribution system to show signs of age/pitting, and the air circulation system to be leaking oil. Customer is aware of age and condition of unit and wanted quote for replacement. Jamie out later today per office. Technician collected $79 service charge.

Wally T.
Unit is low on refrigerant. Customer chose to replace system. We are installing a Bryant 114.
Austin L.
Completed annual maintenance on a 2019 American Standard air conditioner. All electrical, mechanical and safety components of the system check out at this time. Technician unable to clean outdoor unit as water source was broken. Customer will fix and call office back to clean or have it done during furnace check. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2019 American Standard air conditioner. All electrical, mechanical and safety components of the system check out at this time. Technician unable to clean outdoor unit as water source was broken. Customer will fix and call office back to clean or have it done during furnace check. No issues at time of departure.
Robby D.
Made call for cooling upon arrival. No abnormal smells upon walking into home. Custoemr stated around 3-330am she got up and went to living room. Smelt burning. Woke husband up. Husband shut off system through thermostat. Opened window to dissipate smell had system running for roughly 10 minutes. Technician nor customer could smell burning smell. Had customer sniff near furnace. Customer did not smell burning smell from morning. No sign of burning or overheating with blower motor. Control board has browning near resistor. Roughly 2001 furnace. Nothing abnormal in blower wheel, coil or housing. Advised possibly overheating inside blower motor. Also could be board , but hesitant with smell being strong enough to sense throughout home. lack of signs of overheating made it hard to determine where smell is source. With age of system customer would rather replace system then put money towards this unit. On schedule for quote this evening.
Robby D.
Technician out 6/15. For ac check. Found disconnect left off resupplied power. Made call for cooling. System cycled on properly customer stated they haven’t ran ac turned ac on yesterday to find no cool. No charge today.
Austin L.
Completed annual maintenance on the 2020 Brian’s air conditioner. During testing of the unit the technician found no electrical protection device. Technician presented options hb7a-e. Customer chose option a. Technician cycled unit successfully after repair was complete. Customer informed technician Evolution thermostat was not connecting to server. Technician reset power to unit, and power to Internet but could not connect thermostat to server. Another visit will be needed for thermostat update, if unsuccessful we will call Bryant rep.
Austin L.
No cool on a 2007 atlas Butler air conditioner. Upon arrival technician found outdoor fan motor to be seized. Technician presented options hc26b-e. Customer wanted to obtain another quote. Technician informed customer component would need to be ordered as supplier doesn’t have them in stock. Technician collected $79 service charge.
Austin L.
No cool on a 2007 atlas Butler air conditioner. Upon arrival technician found outdoor fan motor to be seized. Technician presented options hc26b-e. Customer wanted to obtain another quote. Technician informed customer component would need to be ordered as supplier doesn’t have them in stock. Technician collected $79 service charge.
Austin L.
Completed annual maintenance on a Bryant Air Conditioner. During testing of the unit, the technician found oil coming from the condenser fan motor, as well as no electrical protection device. Due to age of unit and type of refrigerant it uses the customer will not address concerns today. No issues at time of departure
Austin L.
Completed annual maintenance on a 2021 Bryant air conditioner. All electrical, mechanical, and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device for the unit, as well as the disconnect box not having a cover. Customer not interested in electrical protection device at this time and will address the disconnect box themselves. Technician collected service club renewal today. No issues at time of departure.
Austin L.
Completed annual maintenance on 2021 Bryant air conditioner. All electrical, mechanical, and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device. Technician presented options hb7a-e. Customer declined at this time. Technician left filter by unit for customer as filter had recently been replaced. No issues at time of departure.
Robby D.
Performed yearly maintenance and safety checks on 2018 bryant 80% furnace. Changed 16251 filter. Found voltage absorption system reading 7.5 rated 7.5. Found ignition system reading 46.5 ohms. Inducer motor pulling .43 amps. Blower pulling 4.9 thermostat is not stealing voltage at this time. Found 71 RA 117 SA 46 degree delta t. 18 ppm flu 0 supply. No concerns at this time. customer has humidification system, stated it leaks and is not used anymore.
Austin L.
Completed annual maintenance on a 2002 Concorde furnace. All electrical, mechanical and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device for the furnace, the air circulation system has dirt buildup within the system, and the combustion exhaust system makes grinding noise upon start up but dissipates after operation. The technician also found the burner cells to have rust build up within them. Technician used borescope through cells and high limit and did not find any cracks within the heat exchanger. Customer stated that due to the age of the unit is waiting for this system to fail and will be looking to replace once that happens. Customer did opt for humidifier service today. Technician verified successful operation and drainage of humidification system, set humidity settings at 35%, and replaced 12 water panel. No issues at time of departure.
Robby D.
Performed yearly maintenance and safety checks on 2001 downflow 90% furnace. System is operating properly and within manufacturer specifications at this time with no cause for concern
Austin L.
Completed annual maintenance on a 2014 Bryant furnace. All electrical, mechanical and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device for the furnace. Customer stated they were not interested at this time. Customer opted for humidifier service today. Technician verified successful operation of the humidification system as well as replaced 35 water panel. Technician left air filter beside unit due to air filter just recently being replaced. No issues at time of departure.
Austin L.
Completed annual maintenance on 2004 Bryant furnace. All electrical, mechanical and safety components check out at this time. During testing of unit the technician found multiple concerns. The technician found no electrical protection device for the furnace, the air circulation system has dirt buildup within the system, the voltage enhancement system was outside of manufacturers specifications, the ignition system read just within manufacture specifications, and the flu had a couple spots that showed surface rust and breakdown. Customer stated she was just trying to get through winter with this furnace and only wanted the voltage enhancement system repaired. Technician presented options Hn10 a-e. Customer chose option A. Technician cycled unit after repair was complete. Customer opted for humidifier service today. Technician verified successful operation of the humidification system and replaced 35 water panel. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2018 comfort maker furnace. All electrical, mechanical and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device for the furnace. Customer stated that they were not interested at this time. Technician replaced customer provided 20x25x4 filter and collected service club renewal today. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2021 Comfort maker furnace. All electrical, mechanical and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device for the air circulation system. Technician presented options SH8a-e. Customer stated he will talk it over with his wife and get back with the office if he decides to move forward with the repair.
Austin L.
Completed annual maintenance on a 2005 Bryant furnace. Electrical, mechanical and safety components of the system check out at this time. During inspection of the unit the technician found minor dirt buildup on the air circulation system. This is something to monitor moving forward. Technician collected $198 service club renewal.

Joel T.
Furnace inspection all systems operating at this time.
Austin L.
Completed annual maintenance on a 2004 Bryant furnace. All electrical, mechanical and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device for the furnace, as well as no water detection device for the furnace. Customer stated she is not interested in any repair at this time due to age of the unit. Technician replaced water panel 10.