HVAC Repair In Obetz, Ohio
Sears is proud to be the dependable name in Obetz, OH for everything heating and cooling related. Our highly-skilled professionals have what they need to tackle any job, diagnose any problem and complete any repair. Your comfort is our number one priority.
Find out why we’ve been held in such high esteem since we were founded in 1950. Read reviews from the good folks of Obetz, OH below.
Local Reviews
for Obetz, OH
Our Reviews by City
Robby D.
Performed yearly maintenance and safety checks On 2007 Bryant air handler heat pump how to tablets to drain replaced 1625 one filter. Clean condenser coil, found mindset insulation dry rotted almost non existent. Found voltage absorption system rated 42.5/5 reading 36/5. Found pitting on distribution system. Found burning pitting on board near resistors. Informed customer of concerns customer is aware and is not interested in repairs at this point.
Austin L.
Completed annual maintenance on a 2021 Bryant air conditioner. All electrical, mechanical and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device for the unit. Technician presented options hb7a-e. Customer chose option a. Technician completed repair and cycled unit successfully. Technician left air filter for customer as current filter had recently been changed. No issues at time of departure.
Austin L.
Completed annual maintenance on a Goodman air conditioner. All electrical, mechanical and safety components of the system check out at this time. During testing of the unit, the technician found no electrical protection device for the furnace, the voltage enhancement system out of manufacturers specifications, as well as the initial amp draw being outside of manufacturers specifications. Technician presented options hb7a-e, hn13a-e. Customer wanted quote sent through email. Technician was unable to run compressor due to outdoor temperature. Technician informed customer if any issues occur to contact office. We were just out a couple weeks ago, technician left new filter by the unit. Technician collected service club renewal today. No issues at time of departure.
Robby D.
Returned to complete furnace repair. Continued diagnostics to confirm diagnostic. Found we can manipulate wall control to lock out furnace at 40 degrees. Cannot change temperature adjustment for backup heat past 1 degree. Lockout at 40 allows us to change set temperature as warm as needed without calling for gas heat as long as ambient temp is above 40. Between 35-40 customer understands +2 degree difference will turn on backup heat.
Robby D.
Upon arrival customer stated usually temp is set to 70. Woke up this morning to 73 inside house. Set to 70. Roughly 53 ambient temp. Customer stated thermostat indicated gas heat on, thermostat stated to change filter. Customer changed filter and turned power off to unit. Resupplied power found thermostat reading 68. Eventually rose to 74 to match other temp reading devices in home. Went through setup with lead techs. System set up properly. Lockout at 35 degrees. Went through test runs system cycled on properly in each mode. Did not collect service charge today as tech was out 1/24. Please send tech with lead tech If issue reoccurs if possible.
Robby D.
Responded to no heat. Found code 13 for system lockout running heat pump. Customer stated it ran blower it high speed yesterday. Reset system. Ran syatem test found 1.2 static. Found 20251 filter to have drywall substance on it causing restriction. Replaced filter and cycled system. Blower audibly running less rpm. 6 min high med low test. Furnace cycled through testing properly with .22 static when replaced with a new filter. Sh3a. No further concerns
Robby D.
Performed yearly maintenance and safety checks on 2007 Bryant air handler heat pump. Found concern with outside voltage absorption system outside manufactures specifications as well as browning on control board near resistors informed customer of concerns customer would like to let go at this time and possibly address at a later date. No further concerns at this time
Austin L.
Completing the annual maintenance on a 2006 Bryant heat pump. All electrical, mechanical and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device for the outdoor unit and no water detection device for the indoor unit. Customer declined at this time. Technician recommended customer replace air filter monthly, as the one replaced was very dirty. Customer was under assumption the filters were replaced every three months. No issues at time of departure.
Robby D.
Furnace is modular home furnace. Seers does not work on this type of equipment nor can get parts. Advised customer to call American air Fairfield heating and cooling or pure comfort to have issue looked at
Austin L.
Completed annual maintenance on a 2019 Bryant furnace. All electrical, mechanical and safety components of the system check out at this time. During testing of the unit the technician found no electrical protection device for the furnace. Customer stated they were not interested at this time. Technician replaced 16x25x4 filter covered under service agreement. No issues at time of departure.
Robby D.
Performed yearly maintenance and safety checks on 2019 comfortmaker 80% furnace. Left new 20 x 20 x 1 filter. Performance and safety checks show no cause for concern at this time. Everything is running properly within manufacture specifications at this time
Robby D.
Perfomed yearly maintenance and safety checks on 2010 Bryant evolution furnace. Furnace is running properly and within manufacture specifications at this time. Found concern with inducer motor making grinding noise while running call for pricing and availability for inducer motor supply house does have inducer motor in sock at this time presented options HM 41 a through E customer decided to wait and prepare financially for when inducer motor gets worse
Robby D.
Found drain pan and line bone dry. Poured 3 glasses of water to ensure draining. Found coupler not glued. Glued for customer. Pressures are good no cause for freezing concern. Found filter dirty changed for customer. No further concerns
Robby D.
Returned for completion of Hn1b performed repairs. Cycled unit. System is running properly at this time.
Robby D.
Returned for repair diagnostic. Found issue with thermistors on unit intermittently working. Called for pricing and availability. Presented options hn1 b-e. Customer chose option b. Ordered parts on schedule for repair tomorrow evening
Robby D.
Performed yearly maintenance and safety checks on 2006 Bryant air conditioning system. Unit is running properly and within manufacture specifications at this time.technician found armaflex dry rotting and showing copper also informed customer of surge protection. Customer is not interested in any repair at this time. No further concerns
Robby D.
Upon arrival technician had customer make call for heat as customer stated dog wasn’t the friendliest. Made call, found a 82degree SH, According to manufacture chart desired SH should be around 12, quoted options HJ2 customer chose option A to try to get through summer, customer understands no warranty no guarantee On refrigerants. Informed customer of leak seal but informed not guaranteed to work. Customer chose to pass at this time and proceed with repair filled out leak paper signed and uploaded weighed in refrigerant to desired SH had customer put thermometer in closest vent to furnace. Running within manufacture specifications at this time
Robby D.
Returned to perform thermostat repair and replacement. Performed repair of thermostat cycled unit on thermostat properly communicating to furnace. through thermostat start up process found static running high. Cycled furnace through low medium and high stages for five minutes each furnace successfully started up without fault and ran for five minutes without fall through each stage. Unit successfully cycled off cycled heat pump through thermostat to ensure properly staging. Customer couldn’t find Wi-Fi password will connect thermostat himself.
Robby D.
Returned to complete repair. Performed replacement on thermostat. Unit communicated properly with t-stat during startup process. Cycled unit through low-medium-high stages. Furnace successfully cycled through all stages for 5 min runtimes each. Cycled heat pump to ensure equipment properly cycling. No further concerns at this time
Cody C.
Furnace check on a 2007 Bryant heat pump. Completed performance check, safety check, mechanical check. Everything is working properly at this time.
Cody C.
Furnace check on a 2010 Bryant furnace and 2007 heat pump. Completed performance check, safety check, mechanical check. Everything is working properly at this time.