HVAC Repair Hilliard, Ohio

Serving the Hilliard, Ohio community since 1950, Sears Heating and Cooling offers both repair and replacement on your current heating and cooling system. We offers options to fit any budget as well as financing options. Give us a call today and we will have you up and running again as soon as the same day! Check out our local Hilliard, Ohio reviews below.

Local Reviews
for Hilliard, OH

Sears Heating & Cooling Rated 5.0 out of 5 stars based on 5 customer reviews


Map of Hilliard, OH

yearly service for furnace




Review of Sears Heating & Cooling


Map of Hilliard, OH

Very friendly, very quick!




Review of Sears Heating & Cooling


Map of Hilliard, OH

Great service.




Review of Sears Heating & Cooling

Josh is always professional and friendly. I would want him on my team.


Response from Sears Heating & Cooling:

Thank you for the review!


Map of Hilliard, OH

A/C Tune up




Review of Sears Heating & Cooling

Joel came out and examined my A/C unit. In the vein of safety and the COVID19 pandemic, his service was contactless. He called me after to let me know that everything had checked out and that he left a filter on my front step. Thanks Joel!


Response from Sears Heating & Cooling:

Thank you for the great review!


Map of Hilliard, OH

Trustworthy




Review of Sears Heating & Cooling

On time and always does a great job!


Response from Sears Heating & Cooling:

Thank you for the review!


Josh S.

Josh S.

Concern was HP was not coming on Found main Voltage had been cut to supply heat in garage. Homeowner will fix they did this 2 months ago Offered service contract after he fixed it. He may call in Another concern was system would not maintain. Can’t run system to check.

Near Scioto Darby Rd, Hilliard, OH 43026
Hilliard, OH - Concern was HP was not coming on
Found main Voltage had been cut to supply heat in garage. Homeowner will fix they did this 2 months ago 

Offered service contract after he fixed it. He may call in 

Another concern was system would not maintain. Can’t run system to check.
Josh S.

Josh S.

Replaced condenser motor on carrier 2002 system is clean

Near Landen Farm Rd E, Hilliard, OH 43026
Hilliard, OH - Replaced condenser motor on carrier 2002  system is clean
Mike B.

Mike B.

Perform maintenance on a 2020 Bryant, air conditioner

Near Westbriar Ct, Hilliard, OH 43026
Hilliard, OH - Perform maintenance on a 2020 Bryant, air conditioner
Mike B.

Mike B.

Performing maintenance on a 2012 Bryant, air conditioner

Near Scioto Run Blvd, Hilliard, OH 43026
Hilliard, OH - Performing maintenance on a 2012 Bryant, air conditioner
Josh S.

Josh S.

Ac check on 2018 comfortmaker 14 seer. 16-25-1 filter and I wave added to duct work r410a system. Good temp split

Near Shady Oak Dr, Hilliard, OH 43026
Hilliard, OH - Ac check on 2018 comfortmaker 14 seer.  16-25-1 filter and I wave added to duct work r410a system.  Good temp split
Mike B.

Mike B.

Performing maintenance on a 2013 Bryant air conditioner.

Near Hansen Dr, Hilliard, OH 43026
Hilliard, OH - Performing maintenance on a 2013 Bryant air conditioner.
Josh S.

Josh S.

Furnace and ac check. We installed comfortmaker ac 2018. Furnace is a York brand from 2009

Near Bressler Dr, Hilliard, OH 43026
Hilliard, OH - Furnace and ac check. We installed comfortmaker ac 2018. Furnace is a York brand from 2009
Josh S.

Josh S.

Ac check on system Bryant 2013 16 seer cleaned. Customized return with small bypass flow

Near Wyandot Pl, Hilliard, OH 43026
Hilliard, OH - Ac check on system Bryant 2013 16 seer  cleaned.  Customized return with small bypass flow
Mike B.

Mike B.

Performing maintenance on a 2001 Bryant air conditioner.

Near Coldcreek Dr, Hilliard, OH 43026
Hilliard, OH - Performing maintenance on a 2001 Bryant air conditioner.
Mike B.

Mike B.

2010 Bryant air conditioner. Completed mechanical, safety, and performance test on air conditioner. Found concern with voltage distribution center. Contacts are badly pitted causing arc flashing. Compressor is pulling high amps on start up. Recommended replacing voltage distribution center and adding a performance enhancement kit to assist compressor on start up, reduce energy consumption, and increase compressor life. Showed options on page Hd3. Customer would like to for now. She says she a home warranty. Let her know parts have to be completely failed for ho,e warranty to cover anything. At that time she can have us out to speak with home warranty company and proved an estimate for repairs. All okay at this time

Near Windsock Ct, Hilliard, OH 43026
Hilliard, OH - 2010 Bryant air conditioner. Completed mechanical, safety, and performance test on air conditioner. Found concern with voltage distribution center. Contacts are badly pitted causing arc flashing. Compressor is pulling high amps on start up. Recommended replacing voltage distribution center and adding a performance enhancement kit to assist compressor on start up, reduce energy consumption, and increase compressor life. Showed options on page Hd3. Customer would like to for now. She says she a home warranty. Let her know parts have to be completely failed for ho,e warranty to cover anything. At that time she can have us out to speak with home warranty company and proved an estimate for repairs. All okay at this time
Mike B.

Mike B.

2003 trane gas furnace. Found furnace showing code 3 for pressure switch error. Found pressure switch stuck closed not allowing the start up for sequence of operations. Lightly blew through pressure switch to loosen diaphragm. Furnace fired up and ran normal operation. Recommended replacing pressure Sensor and showed options on page hm11. Customer would like to try to get by Since we are nearing the end of the heating season. Let him know that the issue was not resolved, sensor will most likely get stuck again. He is aware and will call us if the issue progresses. Furnace operational upon departure.

Near Hoffman Farms Dr, Hilliard, OH 43026
Hilliard, OH - 2003 trane gas furnace. Found furnace showing code 3 for pressure switch error. Found pressure switch stuck closed not allowing the start up for sequence of operations. Lightly blew through pressure switch to loosen diaphragm. Furnace fired up and ran normal operation. Recommended replacing pressure Sensor and showed options on page hm11. Customer would like to try to get by Since we are nearing the end of the heating season. Let him know that the issue was not resolved, sensor will most likely get stuck again. He is aware and will call us if the issue progresses. Furnace operational upon departure.
Mike B.

Mike B.

Perform maintenance on a 2018 Bryant, air conditioner

Near Darby Hill Ln, Hilliard, OH 43026
Hilliard, OH - Perform maintenance on a 2018 Bryant, air conditioner
Josh S.

Josh S.

Regular ac check. Replaced water panel 12 and tested

Near Hansen Dr, Hilliard, OH 43026
Mike B.

Mike B.

Performing maintenance on a 2007 air conditioner.

Near Braidwood Dr, Hilliard, OH 43026
Hilliard, OH - Performing maintenance on a 2007 air conditioner.
Mike B.

Mike B.

Performing maintenance on a 2014 Bryant, air conditioner

Near Amberwick Pl, Hilliard, OH 43026
Hilliard, OH - Performing maintenance on a 2014 Bryant, air conditioner
Mike B.

Mike B.

27 year old Lennox air conditioner. Completed mechanical, safety, and performance test on air conditioner. Compressor was unable to start when testing system. Tested with hard start kit and was able to get compressor to run. Compressor is getting to the age where it is having trouble starting without start assistance. Voltage distribution center is very burnt in Contacts pitted. Unit is 27 years old. Recommended replacement of all this distribution center and to add a hard start kit to ensure customer will have cooling the summer. He said he does not use it very often it will most likely not fired up for the first time until August. At that time he will decide whether he would like to do repairs or have an estimate for replacement.All okay at this

Near Darby Glen Ct, Hilliard, OH 43026
Hilliard, OH - 27 year old Lennox air conditioner. Completed mechanical, safety, and performance test on air conditioner. Compressor was unable to start when testing system. Tested with hard start kit and was able to get compressor to run. Compressor is getting to the age where it is having trouble starting without start assistance. Voltage distribution center is very burnt in Contacts pitted. Unit is 27 years old. Recommended replacement of all this distribution center and to add a hard start kit to ensure customer will have cooling the summer. He said he does not use it very often it will most likely not fired up for the first time until August. At that time he will decide whether he would like to do repairs or have an estimate for replacement.All okay at this
Mike B.

Mike B.

Performing maintenance on a 2010 carrier gas furnace.

Near Nadine Park Dr, Hilliard, OH 43026
Hilliard, OH - Performing maintenance on a 2010 carrier gas furnace.
Josh S.

Josh S.

2 stage Bryant 90+% Did system maintenance and checks. Good to go through a cold few weeks to come.

Near Marilyn St, Hilliard, OH 43026
Hilliard, OH - 2 stage Bryant 90+%   Did system maintenance and checks.  Good to go through a cold few weeks to come.
Mike B.

Mike B.

2015 Bryant gas furnace. Thermostat showing call for heat but furnace not running. Showing no trouble code. Left door switch taped last time I was here to prevent power from resetting when removing furnace doors. Found 24 between w and c showing thermostat is calling for heat as normal. Bypassed thermostat and issue still there. Found board not sending voltage to inducer motor. Checked all limits and they are good. When jumping out board unit fired up normal operation. Wiggled all wire inside furnace. Flue pipes outside not blocked or frozen. Wired everything back to normal and furnace ran normal operation. Relay for inducer motor on circuit board having issues closing when there is a call for heat. Recommended replacing circuit board. Customer can receive a $244 credit for warranty. Showed page he3. Chose he3a. Completed repairs and cycl3d unit several times without issue. Tested combustion, all okay at this time.

Near Amberwick Pl, Hilliard, OH 43026
Hilliard, OH - 2015 Bryant gas furnace. Thermostat showing call for heat but furnace not running. Showing no trouble code. Left door switch taped last time I was here to prevent power from resetting when removing furnace doors. Found 24 between w and c showing thermostat is calling for heat as normal. Bypassed thermostat and issue still there. Found board not sending voltage to inducer motor. Checked all limits and they are good. When jumping out board unit fired up normal operation. Wiggled all wire inside furnace. Flue pipes outside not blocked or frozen. Wired everything back to normal and furnace ran normal operation. Relay for inducer motor on circuit board having issues closing when there is a call for heat. Recommended replacing circuit board. Customer can receive a $244 credit for warranty. Showed page he3. Chose he3a. Completed repairs and cycl3d unit several times without issue. Tested combustion, all okay at this time.
Josh S.

Josh S.

Quoted water tank and furnace 80%. Very tight spots

Near Scioto Run Blvd, Hilliard, OH 43026
Hilliard, OH - Quoted water tank and furnace 80%. Very tight spots
Mike B.

Mike B.

2015 Bryant gas furnace. When I arrived thermostat showed there was a call for heat but the furnace was not running and there was no fault code. Just showed normal operation without a call for heat. I took the door off thermostat furnace and taped door switch to begin troubleshooting and system fired up and ran normal operation. Unable to recreate issue. Explained to customer the issue and gave them several options. They could allow issue to progress and get worse so we can troubleshoot or begin by replacing the thermostat. I wiggled all connection for the thermostat wire and found no issues, so issue lies either with thermostat or the circuit board. Showed options on page hh5. Customer would like to replace thermostat himself. Unit was operational when I left.

Near Amberwick Pl, Hilliard, OH 43026
Hilliard, OH - 2015 Bryant gas furnace. When I arrived thermostat showed there was a call for heat but the furnace was not running and there was no fault code. Just showed normal operation without a call for heat. I took the door off thermostat furnace and taped door switch to begin troubleshooting and system fired up and ran normal operation. Unable to recreate issue. Explained to customer the issue and gave them several options. They could allow issue to progress and get worse so we can troubleshoot or begin by replacing the thermostat. I wiggled all connection for the thermostat wire and found no issues, so issue lies either with thermostat or the circuit board. Showed options on page hh5. Customer would like to replace thermostat himself. Unit was operational when I left.
Jamie S.

Jamie S.

Proposed cost of installation of furnace and air condition. Two stage air-conditioning for dehumidifying the house much better over the summer

Near Nova Park Ln, Hilliard, OH 43026
Hilliard, OH - Proposed cost of installation of furnace and air condition. Two stage air-conditioning for dehumidifying the house much better over the summer
Mike B.

Mike B.

2015 Bryant gas furnace. Found concern with flame sensing system not proving flame. I had cleaned it good hen I was out for maintenance. Flame rod is hardly even dirty. Recommended replacing aflame sensing system. Customer can get $204 credit towards repair per office. Showed options on page hm15. Chose hm15a. Completed repair and cycled unit. Performed combustion analysis. Slightly adjusted gas pressure is high and low stage. 4 ppm CO/ 8.7 % O2/ 105 degree stack temp. Temp rise is 52 degrees. All okay at this time.

Near Amberwick Pl, Hilliard, OH 43026
Hilliard, OH - 2015 Bryant gas furnace. Found concern with flame sensing system not proving flame. I had cleaned it good hen I was out for maintenance. Flame rod is hardly even dirty. Recommended replacing aflame sensing system. Customer can get $204 credit towards repair per office. Showed options on page hm15. Chose hm15a. Completed repair and cycled unit. Performed combustion analysis. Slightly adjusted gas pressure is high and low stage. 4 ppm CO/ 8.7 % O2/ 105 degree stack temp. Temp rise is 52 degrees. All okay at this time.
Jamie S.

Jamie S.

New furnace and air conditioner estimate in Hilliard, Ohio.

Near Shelby Ln, Hilliard, OH 43026
Hilliard, OH - New furnace and air conditioner estimate in Hilliard, Ohio.
Brian S.

Brian S.

Fireplace maintenance

Near Avery Rd, Hilliard, OH 43026