HVAC Repair In Canal Winchester, Ohio

Sears is proud to be the dependable name in Canal Winchester, OH for everything heating and cooling related. Our highly-skilled professionals have what they need to tackle any job, diagnose any problem and complete any repair. Your comfort is our number one priority.

Find out why we’ve been held in such high esteem since we were founded in 1950. Read reviews from the good folks of Canal Winchester, OH below.

Recent Jobs and Reviews in Canal Winchester, OH

Job Locations and Reviews

Robby D.
Robby D. Checked in
Performed yearly maintenance and safety checks on 2011 Lennox air conditioning system. Found 45/10 voltage absorption system reading 45/10. 67 inrush amps. 88–108 hard start reading 104. Cleaned condenser. Replaced customer supplied 18254
Canal Winchester, OH 43110
Canal Winchester, OH - Ac check 2012 Bryant 45/5= capacitor. Filter 16-25-1
Josh S.
Josh S. Checked in
Ac check 2012 Bryant 45/5= capacitor. Filter 16-25-1
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Performed yearly maintenance and safety checks on 22 AC system found 35/5 voltage absorption system reading 35/5 found 48 in Rush amps. Replaced 1625 one filter no issues found at this point in time.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Responded to no heat thermostat calling for heat. 66 in home 73 set temperature. Found code 32 for pressure switch found inducer pulling 0-3 inWC customer has exterior of home being panted. Painters covered up concentric kit not allowing proper exhaust. Removed cover per customers request to restore heat. Furnace cycled on properly without fault. 0 ppm co in supply. Dirty 16254 filter. Replaced 10/15. replaced customer supplied filter. No further issues.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Returned to repair. Replace blower motor and control board. Further diagnostics found identity chip faulty no allowing proper communication with blower motor. Replaced chip furnace cycled on properly. Running with 11%o2. 14 ppm co in flu. 0 ppm co in supply. 46 degree dletat. No further issues at this time.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Called in morning to quote for repair blower motor power choke and possible board. Replaced blower motor. New motor has different wiring connections as well as smaller plug not able to be used power choke also not able to be connected. No paperwork with blower. When installed blower would not operate from board. Will need to double check parts Monday and require at that point.
Canal Winchester, OH 43110
Wally T.
Wally T. Checked in
Annual maintenance check on a rheem air conditioner
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Upon arrival customer stated it had started running. Found furnace running. Cycled furnace several times to find no fault occurring. Found charred/weak flame sensing system. Presented options hm15a-e. Customer chose option a. Performed repair and cycled furnace. System running with 10.5% o2. 12 ppm co in flu. 0 ppm co in supply. 45 degree deltat clean 16251 filter. Found floor drain to be clogged advised may want plumber to look at drains. Strong Oder coming from drain.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Performed  yearly maintenance  and safety checks on 2020 Bryant furnace in attic. Furnace is running with 10.1%o2. 9 ppm so in flu. 49 ohm igntion  system 45 degree dletat. Furnace cycled into second stage properly.system running with 7.5%o2. 33 ppmco in flu. 0 ppm co in supply. Cleaned flame sensor. Customer maintains 16254 filter. Also performed yearly maintenance  and safety checks on 20 Bryant furnace in basement. Previous  technician mentioned excess noise in motor. Found noise to be associated  with airflow in filter cabinet. After Removing filter noise stops. Furnace running with 12.4%o2. 20 ppm co in flu. 34 degree deltat. Furnace cycled into second stage properly.  Running with 7.5% o2 48 ppm co in flu. 0 ppm co in supply.  50 degree deltat.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Thermostat indicating call for cooling. Found code 3 for pressure switch stuck open. Reset control board. Made call for heating. Found inducer motor having issues running. Motor not seized. Seems as if something holding wheel from spinning removed motor to loom for critters. Founs bead of caulk stuck around blower wheel. Attempted to remove foreign object Unsuccessfully messed with wheel to try to free motor. Cannot remove object. Called for pricing and Availability for motor and pressure switches. Not in stock. Presented hm7 with possibility of returning for repair Tuesday or Wednesday cust9mer not ready for repair and will call next week to schedule repair.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Performed yearly maintenance and safety checks on 1998 Bryant furnace. Found dry bearing noise associated with inducer. Found ignition system reading 90 ohms. Also found voltage absorption system outside manufacture specifications.customer wants to wait issues out and address when fault occurs also Performed maintenance on 2017 rheem furnace. Found 40/5 voltage absorption system reading 40/5 cleaned coil. No concerns at this time.
Canal Winchester, OH 43110
Austin L.
Austin L. Checked in
Completed annual maintenance on a 2021 comfortmaker furnace. And during testing of the unit the technician found no electrical protection device, the air filter to be installed incorrectly, and ductwork to have large amounts of dust/hair build up. Customer not interested in electrical protection device at this time. Technician left fresh air corporation information for duct cleaning, as well as iwave information for air cleaner. Customer may call back at a later time for the install. Technician left filter beside unit as filter has recently been changed, and created inspection hole for combustion analysis. No issues at time of departure.
Canal Winchester, OH 43110
Austin L.
Austin L. Checked in
Completed annual maintenance on a 2021 comfortmaker air conditioner. During testing of the unit, the technician found no electrical protection device and the outdoor unit to be very dirty. Technician explained this would cause issues for the unit to keep up. Customer not interested in electrical protection device today. Technician left air filter beside unit as filter had been recently changed. No issues at time of departure.
Canal Winchester, OH 43110
Austin L.
Austin L. Checked in
No cool on a 2019 comfortmaker air conditioner. Upon arrival technician found voltage enhancement system to be dead on both sides, as well as outdoor unit to be very dirty. Technician presented options Hn13a-e. Customer chose option B. Technician replaced voltage enhancement system and installed electrical protection device. Technician cycled unit successfully after repairs were completed. 18° temperature split. No issues at time of departure.
Canal Winchester, OH 43110
Austin L.
Austin L. Checked in
No cool on a 2019 comfortmaker air conditioner. Upon arrival technician found voltage enhancement system to be dead on both sides, as well as outdoor unit to be very dirty. Technician presented options Hn13a-e. Customer chose option B. Technician replaced voltage enhancement system and installed electrical protection device. Technician cycled unit successfully after repairs were completed. 18° temperature split. No issues at time of departure.
Canal Winchester, OH 43110
Wally T.
Wally T. Checked in
Replaced failed capacitor on a Carrier air conditioner
Canal Winchester, OH 43110
Canal Winchester, OH - Cost to replace air conditioning. Price to install new air conditioner.
Jamie S.
Jamie S. Checked in
Cost to replace air conditioning. Price to install new air conditioner.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Completion Notes: Edit Completion Notes Made call for cooling upon arrival. Replaced customer supplied 16251. Found-2.5 psi in system. Advised moisture has been introduced into system and may seize compressor. On schedule for quote today 12-1.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Customer has leak above hot water tank. Old silinoid valve abandoned with old saddle valve. Plastic tube melted from hot water supply spraying water. Saddle valve also leaking. Advised customer technician can replace saddle valve with new valve to seal hole and rid of tubing. Customer called plumber friend to help out. Should be taken care of tomorrow. Collected service charge.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Completion Notes: Edit Completion Notes Returned for diagnostic pilot won’t keep lit on 21 hot water tank. Found weak thermocouple not allowing gas valve to stay lit. HM15 a-e customer chose option a. 65 dollar limited manufacture warranty credit 5% senior citizens discount. Performed repair. Cycled system. Allowed to run for 5-10 minutes. Unit running upon arrival. Warm water coming from faucet. No further concerns at this point in time.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Upon arrival customer has emailed invoice with measure quick pictures. Technician did ac check. Stated system was low on charge but performing properly. Quoted over 500 to top off system. Found system was slightly low on refrigerant maybe a couple ounces. Found no leak in attic or around condenser. System was installed 21 in march. Explained different weather conditions effect refrigerant pressures, measure quick is new technology with better equipment takes reading from probes calculates readings and gives perfect in lab goal points. System is running properly and in acceptable ranges. 65 in house customer stated system had cooled very well since installed.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Made call for cooling upon arrival. Found upflow furnace has p trap. Found clog in p trap not allowing drain to properly dispose of condensation. Informed customer of issue and options moving forward. Offered to cut out trap and replace with clean out tee or blow out p trap. Customer opted to have p trap removed and replaced with clean out tee that he can blow out or pour cleaning solution down. Advised white distilled vinegar is the best cleaning agent annually. Advised customer of yearly maintenance customer will get back to us about routine maintenance.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Upon arrival founs heat pump in lockout. Found low pressure. Crack in low pressure switch. Patched hole and charged system. Found 18 degree deltat. 72 RA 54 SA. NO FURTHER CONCERNS UNIT IS RUNNING PROPERLY AND HOW IT SHOULD BEFORE DEPARTURE
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Performed yearly maintenance and safety checks on thousand six Rheem air conditioning system. Found 45/5 resorption system reading 45/5. Found high ohms and start winding of fan motor as well as rust on exterior of motor. Found insulation on mindset dry rotted missing chunks. HC8 for motor. Customer chose option A. Paid half will return this afternoon to replace part. Cleaned condenser. 68 RA. 50 SA. added tabs to drain. 413 filter.
Canal Winchester, OH 43110
Robby D.
Robby D. Checked in
Returned to wash ac unit. Washed system
Canal Winchester, OH 43110