Before departure customer called back and said door didn’t seem shut. He pushed door in and unit lit and cycled on. Customer has concerns wants someone to check to see if doors need adjusted.. advised office will call in morning to schedule to have doors looked at.
Robby D.
Performed yearly maintenance and safety checks on 2012 Bryant furnace. Found no sign of gas leak via electronic detector. 11% o2 8 ppm co in flu 0 ppm co in supply. Found significant rust in furnace. Customer does not recall being informed this before. Flu pipe runs over finished ceiling possibly leading to condescending draining into furnace. Customer will let go due to age of furnace and expecting replacement in next couple years. No further concer s
Robby D.
Performed dyealry maintenance and safety checks on Lennox 90% furnace. Found furnace running with 7.8% o2 9 ppm o in flu. 0 in supply. Found leak in gas line. Confirmed with bubbles. Presented leak to customer repair option HR4. Customer chose option a. Performed repair tested with electronic leak detector and double checked with bubbles with customer to ensure customer satisfaction. No sign of leak at this time 75 RA 137 SA 62 degree delta t. Offered to replace humidifier panel. Customer was instructed to turn off in winter and on in summer. Advised that is not accurate. Humidifier is needed in winter to add moisture content to the air. No further concerns at this time. Assigned to: Robby
Robby D.
Responded to no cool situation on 2020 system. Found 35/5 voltage absorption system reading 3.2nf/4.8. Presented hn13 a-e with option a being covered under full parts and labor. Customer chose option b to have upgraded voltage absorption system installed. 413 filter could be replaced customer accepted 84 for replacement filter. .. performed yearly maintenance and safety checks on 2020 Bryant furnace. 79RA 119 SA. 40 degree delta t.14 ppm co in flu. 0 ppm co in supply. No concerns at this point in time.
Austin L.
Technician back to complete repairs. Technician verified. Successful alignment and operation of the air circulation system after repairs were complete. Technician recommended blower wheel cleaning or replacement again due to amount of dirt build up. 19° temperature split a time of departure. No issues at time of departure.
Austin L.
Technician back to complete repairs. Technician verified. Successful alignment and operation of the air circulation system after repairs were complete. Technician recommended blower wheel cleaning or replacement again due to amount of dirt build up. 19° temperature split a time of departure. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2006 Sanyo furnace. During testing of the unit, the technician found the air circulation system to have dirt build up within the system, the air filter replaced to have not been changed in some time, and no electrical protection device. Customer was unaware one inch filters were changed monthly. Technician presented options hb7a-e. Customer not interested at this time. Technician recommended customer buy CO detectors as none were in the household. Technician collected service club renewal today. No issues at time of departure.
Austin L.
Completed annual maintenance on a 2006 Sanyo furnace. During testing of the unit, the technician found the air circulation system to have dirt build up within the system, the air filter replaced to have not been changed in some time, and no electrical protection device. Customer was unaware one inch filters were changed monthly. Technician presented options hb7a-e. Customer not interested at this time. Technician recommended customer buy CO detectors as none were in the household. Technician collected service club renewal today. No issues at time of departure.
Robby D.
Customer arrived and showed technician around to condenser. Heard humming nothing coming on. Voltage absorption system reading 0/0. Presented hn13 a-e. Customer will wait for now and call us back with approved repair.collected service charge today
Austin L.
Completed annual maintenance on a 1994 trane air conditioner. During testing of the unit, the technician found the outdoor fan motor to be leaking oil, the voltage enhancement system to be outside of manufacturers specifications, the voltage distribution system shows signs of age/pitting, no electrical protection device, and overall outdoor unit condition to be rusted/discolored. Customer stated due to age of the unit and type of refrigerant. No longer being available. No repairs will be made. Customer will call in for replacement when unit fails. No issues at time of departure.
Robby D.
Performed yearly maintenance and safety checks on 2022 Bryant air-conditioning system. Found 35/5 voltage absorption system reading 34.6/4.9. 74 RA 54 SA found no sign of overheating in disconnect or on voltage distribution system. replaced 16251 filter cleaned condenser added tabs to drain. No issues at this point in time

Joel T.
Set preferences for over humidify to help customer as they would like it cool. System will overrun two degrees and attempt. Customer will monitor and let us know.

Joel T.
Inspection found voltage absorption component failed. Replaced today and cycled equipment. Drain clear and filter is clean. Unit is a 1998 r22 Goodman unit. Advise customer to budget for new equipment as unit will be obsolete soon.
Robby D.
Performed yearly maintenance and safety checks on ac system. Cannot read tag. Cleaned condenser. 72 RA 52 SA. added tabs to drain founs disconnect door not properly secured in housing. Secured lid properly.customer has young son. Advised and demonstrated how easy it is to get to live wires of disconnect without tools.. Advised to get lock to keep unwanted fingers out. Customer inquired about low airflow upstairs. Advised to keep doors open and possible options to suffice customer will look into mini splits and room sensors. No further concerns at this time
Robby D.
Perform maintenance and safety checks on 2006 Bryants air-conditioning system found 188-226 hard start kit reading 213. Found 40/5 voltage absorption system reading 40/5. 37 inrush amps. Found no sign of pitting of overheating on voltage distribution system. Informed customer of surge protection and air purification system. Customer is not interested in accessories at this point in time.
Robby D.
Responded to no heat. Customer changed batteries in thermostat. Stated it was working yesterday but nothing is operational today. Found blown fuse. Replaced fuse. Found no sign of short. Tested equipment. Equipment cycled properly in heat. 70 RA 110 SA. Allowed furnace to run for 10-15 minutes system is operation properly with no cause for concerns
Robby D.
Performed yearly maintenance and safety checks on 2011 Rheem air conditioning system.64 RA 44SA. added tabs. Cleaned coil. 45/5 voltage absorption system reading 45/5. No sign of overheating or pitting inside disconnect or voltage distribution system. 47 inrush amps. 88-108 hard start reading 104. Informed customer of surge protection customer is not interested at this point in time.
Robby D.
Performed yearly maintenance and safety checks on Lennox air conditioner. 68 RA 47 SA 21 degree delta t. Technician found multiple concerns including 40/5 voltage absorption system reading 37.2/4.2. Found voltage distribution system significantly pitting showing signs of overheating and wear and tear. Found inrush amps of 89 manufacture specifications state 68. Also found no surge protection on system. Presented concerns with hn13 a-e to address issues. Customer chose option D. Performed repair and cycled system to ensure operation. No concerns upon departure
Robby D.
Performed yearly maintenance and safety checks on 2021 Bryants air conditioning system. Added tablets to condensation drain cleaned condenser coil found 70/7.5 voltage absorption system reading 69.75/7.45 no pitting overheating on voltage distribution system or disconnect. Cleaned condenser. No concerns at this point in time.
Robby D.
Fireplace off upon arrival customer stated fireplace would run for 30-40 min then shut off pilot remained on. Found thermocouple good conditions. Found gas valve faulted after a while of running. Supply house closed. Will call tomorrow for quote

Wally T.
Replaced flame sensor and capacitor on a Carrier furnace